Does Carrier Commercial HVAC have guidelines for evacuating and recharging refrigerant lines in split systems, like the Carrier Performance™ Series ductless units, and what refrigerants are approved for use?

Carrier Commercial HVAC typically provides guidelines for evacuating and recharging refrigerant lines in split systems, including ductless units like the Carrier Performance™ Series. Proper evacuation and refrigerant charging are critical for system performance and efficiency. Here are general steps and information regarding refrigerants:

Evacuating and Recharging Refrigerant Lines:
1. Safety Precautions: Always prioritize safety by wearing appropriate personal protective equipment (PPE) and following industry safety guidelines.
2. Equipment Check: Ensure that the HVAC system is in good working condition and there are no visible refrigerant leaks.
3. Evacuation Process:
* Use a high-quality vacuum pump to evacuate the refrigerant lines. Attach the pump to the service ports on the outdoor unit and open the valves.
* Evacuate the lines to the manufacturer's recommended vacuum level. This typically involves pulling a vacuum of 500 microns or less.
* Monitor the vacuum pump and close the valves when the desired vacuum level is achieved.
4. Leak Testing: After completing the evacuation process, perform a leak test to confirm that there are no refrigerant leaks. Use a leak detector or soap bubbles to check for leaks at connections and joints.
5. Refrigerant Charging:
* Consult the unit's technical data or manufacturer's guidelines to determine the appropriate refrigerant type and charge amount for your specific system. Common refrigerants include R-410A and R-32.
* Attach a refrigerant manifold gauge set to the service ports on the outdoor and indoor units.
* Connect the refrigerant container to the manifold and slowly charge the system with refrigerant while monitoring the system pressures and temperatures.
* Follow a superheat or subcooling method to ensure the correct refrigerant charge. Adjust the refrigerant charge as needed to achieve the specified superheat or subcooling values.
6. System Performance Testing: After charging the refrigerant, check the system's performance by verifying proper airflow, temperature, and pressure readings. Make any necessary adjustments to achieve the desired performance.

Approved Refrigerants:
The approved refrigerants for Carrier Performance™ Series ductless units and other split systems may vary depending on the specific model and regional regulations. However, Carrier has been transitioning to more environmentally friendly refrigerants in recent years due to regulations aimed at reducing the use of high-global warming potential (GWP) refrigerants. Commonly used refrigerants include:
1. R-410A: This refrigerant has been widely used in ductless and split systems for its cooling efficiency. However, it has a relatively high GWP.
2. R-32: R-32 is considered a more environmentally friendly alternative to R-410A due to its lower GWP. It is becoming increasingly common in newer Carrier systems.

It's essential to consult the manufacturer's guidelines, technical documentation, or contact Carrier Commercial HVAC directly to determine the approved refrigerants for your specific system. Additionally, follow local and national regulations regarding the handling, disposal, and recycling of refrigerants to ensure compliance with environmental standards.