Replacing the evaporator coil in your American Standard Platinum 19 Air Conditioner is a complex and labor-intensive task that should be undertaken by a qualified HVAC technician. It involves working with refrigerants and specialized equipment, and any mistakes can lead to inefficient cooling, system damage, or safety hazards. That being said, I can provide a general overview of the steps involved in replacing an evaporator coil.

Safety Precautions: Before you begin, ensure that you have the necessary safety equipment, including gloves and safety glasses, to protect yourself from refrigerant exposure. Additionally, turn off the power to your air conditioner at the circuit breaker to prevent any electrical accidents.
Refrigerant Recovery: Properly recover the refrigerant from the system. This involves connecting a recovery machine to the air conditioner's refrigerant lines to capture and store the refrigerant safely. Never release refrigerant into the atmosphere, as it is harmful to the environment.
Access the Coil: Gain access to the evaporator coil. This typically involves removing the access panels or the indoor unit's casing. Be careful not to damage any components while doing this.
Disconnect Electrical Connections: Carefully disconnect all electrical connections to the old evaporator coil. Label wires if necessary to ensure correct reconnection later.
Remove the Old Coil: Unbolt and remove the old evaporator coil from its housing. Be cautious not to damage any surrounding components during removal.
Prepare the New Coil: Prepare the new evaporator coil by ensuring it matches the specifications of your American Standard Platinum 19 Air Conditioner. Check for any included gaskets or seals and inspect the coil for damage before installation.
Install the New Coil: Carefully install the new evaporator coil into the housing. Ensure it is positioned correctly and securely fastened in place.
Reconnect Electrical Connections: Reconnect all the electrical wires to the new evaporator coil, referring to the labels you made during disconnection.
Pressure Test: Before recharging the system with refrigerant, perform a pressure test to check for any leaks in the system. This is a critical step to ensure the integrity of your AC system.
Vacuum and Recharge: Evacuate the air from the system using a vacuum pump. This removes any moisture or impurities that could damage the system. Once the system is properly evacuated, recharge it with the recovered refrigerant. Be sure to weigh the refrigerant to ensure the correct charge level.
Check for Proper Operation: After recharging the system, turn it on and monitor its performance. Check for any unusual noises, leaks, or other issues. Verify that the air conditioner is cooling your space effectively.
Seal and Insulate: Properly seal and insulate all access points and connections to prevent air leaks and maintain energy efficiency.
Documentation: Keep detailed records of the replacement, including the type and amount of refrigerant used, pressure test results, and any other relevant information. This documentation can be helpful for future maintenance and service.

In summary, replacing the evaporator coil in your American Standard Platinum 19 Air Conditioner is a task best left to trained HVAC professionals. It involves several intricate steps, including handling refrigerants, electrical connections, and system testing. Attempting this task without the necessary knowledge and equipment can lead to costly mistakes and potential safety hazards. Always consult a licensed HVAC technician to ensure a successful and safe evaporator coil replacement.