Ask us anything

How to replace the reversing valve in my American Standard Heritage 20 Heat Pump?

Replacing the reversing valve in your American Standard Heritage 20 Heat Pump is a complex and advanced HVAC repair task that should only be undertaken by a licensed and experienced HVAC technician. The reversing valve is a critical component responsible for changing the direction of refrigerant flow, allowing your heat pump to switch between heating and cooling modes. Here's a general overview of the steps involved, but please note that this is not a DIY task:

1. Safety First: Prioritize safety by turning off the power to the heat pump at the circuit breaker to avoid electrical accidents. Additionally, ensure you have the necessary personal protective equipment (PPE), including safety glasses and gloves.
2. Gather Materials and Tools: Collect the required tools and materials, including a replacement reversing valve that matches the specifications of your American Standard Heritage 20 Heat Pump, refrigerant recovery equipment, a recovery cylinder, a vacuum pump, manifold gauge set, torque wrench, pipe cutter, and brazing equipment.
3. Refrigerant Recovery: Properly recover the refrigerant from the system to prevent its release into the atmosphere. This involves connecting a recovery machine to the refrigerant lines and capturing the refrigerant in a recovery cylinder. Follow all EPA regulations and guidelines for refrigerant handling.
4. Access the Reversing Valve: Gain access to the reversing valve, which is typically located in the outdoor unit of the heat pump. This may require removing the access panels and any other obstructions that prevent access to the valve.
5. Identify and Document Connections: Take clear photographs or create a detailed diagram of the existing refrigerant lines and electrical connections to the reversing valve. Proper documentation is essential for reassembly.
6. Disconnect Refrigerant Lines: Carefully disconnect the refrigerant lines connected to the reversing valve. Use a pipe cutter to cut the lines cleanly. Cap the ends to prevent debris from entering the system.
7. Disconnect Electrical Connections: Disconnect the electrical wires and connectors that are attached to the reversing valve. Label these wires to ensure correct reconnection later.
8. Remove the Old Reversing Valve: Unbolt and remove the old reversing valve from its mounting position. Be careful not to damage any surrounding components during removal.
9. Install the New Reversing Valve: Position the new reversing valve in place and secure it with the appropriate bolts or fasteners. Make sure it is correctly oriented to match the refrigerant and electrical connections.
10. Reconnect Electrical and Refrigerant Lines: Reconnect the electrical wires and connectors to the new reversing valve, using your documentation as a guide. Then, connect the refrigerant lines to the appropriate ports, ensuring that they are properly brazed or flared.
11. Pressure Test and Vacuum: Pressure test the system to check for any refrigerant leaks. Once confirmed, use a vacuum pump to remove any moisture and impurities from the system. Evacuate the system to the manufacturer's recommended vacuum level.
12. Recharge the System: Weigh the refrigerant and charge the system to the manufacturer's specifications. Use a manifold gauge set to monitor the pressures during the charging process.
13. Test the Heat Pump: Turn on the power and test the heat pump to ensure it is operating correctly in both heating and cooling modes. Check for any unusual noises, leaks, or other issues.
14. Documentation: Maintain detailed records of the replacement, including the type and amount of refrigerant used, pressure test results, and any other relevant information.

In summary, replacing the reversing valve in your American Standard Heritage 20 Heat Pump is a complex and specialized task that should be left to qualified HVAC technicians. It involves working with refrigerants, electrical components, and precise installation procedures. Attempting this repair without the necessary knowledge and equipment can lead to system damage and safety hazards. Always consult a licensed HVAC professional to ensure a successful and safe reversing valve replacement.
FAQ
Connect to virtual expert

Our virtual experts can diagnose your issue and resolve simple problems.